Datalogic Memor Manuale Utente

Navigare online o scaricare Manuale Utente per Computer palmari Datalogic Memor. Datalogic Memor User`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 117
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Datalogic Memor™
©2009 Datalogic Mobile S.r.l.
09/09
822000890
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
User’s Manual
Vedere la pagina 0
1 2 3 4 5 6 ... 116 117

Sommario

Pagina 1 - User’s Manual

Datalogic Memor™©2009 Datalogic Mobile S.r.l.09/09822000890www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara

Pagina 2

ATTENZIONE Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. L’apertura dello scomparto, o la manute

Pagina 3

DATALOGIC MEMOR™ 1 4 4.3 CLEANING THE MOBILE COMPUTER Periodically clean the Datalogic Memor™ with a slightly dampened cloth. 80

Pagina 4

TECHNICAL FEATURES 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Memor™ Common Features Electrical Features Power DC Supply 5 V ± 5% Ba

Pagina 5 - REFERENCES

DATALOGIC MEMOR™ 1 5 Hardware Features FLASH 256 MB RAM 128 MB Microprocessor Marvell PXA 310 624 MHz Audio Rear Speaker for beeps and ringing tones

Pagina 6 - SAFETY REGULATIONS

TECHNICAL FEATURES 5 Datalogic Memor™ Optical Features Datalogic Memor™ 1D Models Maximum resolution 0.10 mm / 4 mils Skew angle ± 50° Pitch angle

Pagina 7 - LASER SAFETY

DATALOGIC MEMOR™ 1 5 5.2 READING DIAGRAM Datalogic Memor™ 1D Typical Reading Diagram - Reading Zones (10° skew angle) 100 200 300 400 0 200 100 300

Pagina 8 - I D F E

TEST CODES 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784

Pagina 9

DATALOGIC MEMOR™ 1 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784

Pagina 10

TEST CODES 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 Ìtestw

Pagina 11

DATALOGIC MEMOR™ 1 6 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example 88

Pagina 12

GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile

Pagina 13 - LED CLASS

ACHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, können ein gefährliches Laser

Pagina 14 - Information for the User

GSM Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands.

Pagina 15 - FCC COMPLIANCE

INDEX A Accessories; 10 ActiveSync® Remote; 61 B Backup Directory File Management; 73 Bluetooth® Manager Device Setup; 62 Buttons; 47 C Charging the

Pagina 16 - PATENTS

Test Codes; 85 U USB Connection; 11 Using the Joystick; 27 Using the Stylus; 26 V Volume Settings; 56 W WEEE Compliance; xvii Windows Connections; 60

Pagina 17 - WEEE COMPLIANCE

Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the déclare que le bescheini

Pagina 18

EN 62311:2008 : ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)

Pagina 19

Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the déclare que le beschein

Pagina 20 - GENERAL VIEW

ETSI EN 301 511 V9.0.2, MARCH 2003 : GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS (GSM); HARMONIZED EN FOR MOBILE STATIONS IN THE GSM 900 AND GSM 1800

Pagina 21 - 1 INTRODUCTION

Datalogic Memor™©2009 Datalogic Mobile S.r.l.09/09822000890www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara

Pagina 22 - 1.2 MODELS DESCRIPTION

ATTENTION L’utilisation d’instruments optiques avec le scanneur augmente le danger pour les yeux. Les instruments optiques comprennent les jumelles,

Pagina 23

LED CLASS According to EN60825-1:2001, the Datalogic Memor™ 1D models which use the green spot LED are also CLASS 1 LED PRODUCTS. APPARECCHIO LED C

Pagina 24 - − 1 CD-ROM Datalogic SDK

Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify

Pagina 25

FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the eq

Pagina 26

SAR COMPLIANCE - This product has been tested and found to comply with the following standards: - OET BULLETIN 65 SUPPLEMENT C: evaluating compli

Pagina 27 - 1.5 INSTALLING THE SIM CARD

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato

Pagina 28

 éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte  récupérer les matériaux dans le

Pagina 29 - 1.5.1 Removing the SIM Card

CHINA ROHS POLLUTION CONTROL LOGOS Toxic or Hazardous Substances and Elements for DL-MEMOR Part name Pb Hg Cd Cr6+ PBB PBDE Upper Case O O O O O O

Pagina 30 - 1.7 OPERATING SYSTEM

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Memor™ - User's Manual Sof

Pagina 31 - 2 CONNECTIONS

GENERAL VIEW CHI D KBJA ELMF G A) QVGA 64K Color Display B) Good Read or User Programmable LED C) Charging Status LED D) Speaker E) Scan K

Pagina 32

INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC MEMOR™ DESCRIPTION The newly updated Datalogic Memor™ mobile computer maximizes a compact and light w

Pagina 33

DATALOGIC MEMOR™ 1 1 are essential. Datalogic’s patented Green Spot good read feedback makes Memor’s laser scanner intuitive while reducing errors. Th

Pagina 34

INTRODUCTION 1 • 944201015 DL-Memor+802.11g+BT+2D+WM6.1 Datalogic Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std 2

Pagina 35 - 2.3 RS232 CONNECTION

DATALOGIC MEMOR™ 1 1 1.3 PACKAGE CONTENTS The Datalogic Memor™ package contains: − 1 Datalogic Memor™ mobile computer − 1 AC/DC power supply − 1 E

Pagina 36 - 2.4 WLAN CONNECTION

INTRODUCTION 1 1.4 INSERTING A MICRO SD CARD Datalogic Memor™ provides the possibility to add a Micro SD memory storage card. To access the Micro S

Pagina 37 - could get warm

DATALOGIC MEMOR™ 1 1 b. Shift the cardholder to the left and then pull it up; insert the Micro SD card with the written part upward. c.

Pagina 38 - 2.5 WPAN CONNECTION

INTRODUCTION 1 1.5 INSTALLING THE SIM CARD To correctly insert the SIM Card, proceed as follows: 1. Turn off the Datalogic Memor™. 2. Press the

Pagina 39 - 2.6 WWAN CONNECTION

DATALOGIC MEMOR™ 1 1 4. Shift the cardholder to the left and then pull it up; insert the SIM Card with its contacts downward and its round corner at

Pagina 40 - could get

INTRODUCTION 1 1.5.1 Removing the SIM Card To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slot. NO

Pagina 41 - 2.7 CONNECTION CABLES

CONTENTS REFERENCES...v Conventions ...

Pagina 42

DATALOGIC MEMOR™ 1 1 1.6 ACCESSORIES  Cradles 94A151111 DL-Memor Single Cradle w Aux. Slot 94A151121 Dock Memor Vehicle w Power Adapter  Batter

Pagina 43

CONNECTIONS 2 2 CONNECTIONS 2.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Datalogic Memor™ to a host computer

Pagina 44 - 3 USE AND FUNCTIONING

DATALOGIC MEMOR™ 1 2 NOTE Connection through the cradle is compliant to 1.1 USB standard. NOTE The actual data transfer speed can be appreciably lo

Pagina 45

CONNECTIONS 2 2.2 CONNECTION TO USB PERIPHERALS You can use a standard A (4 pin female) to mini A (5 pin male) USB cable to connect the Datalogic Me

Pagina 46 - 3.1.1 Using the Stylus

DATALOGIC MEMOR™ 1 2 NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed. 14

Pagina 47 - 3.1.2 Using the Joystick

CONNECTIONS 2 2.3 RS232 CONNECTION You can use a cable to directly connect the Datalogic Memor™ to a host computer to transfer data through the RS232

Pagina 48 - Welcome Wizard Screen

DATALOGIC MEMOR™ 1 2 2.4 WLAN CONNECTION Datalogic Memor™ 802.11b/g radio models can communicate with the host using the on-board radio frequency c

Pagina 49 - 3.3.1 Laser Data Capture

CONNECTIONS 2 NOTE 802.11g radio module is on by default, in order to avoid wasting energy, you can switch it off using the Wireless Communications a

Pagina 50 - 3.3.2 Imager Data Capture

DATALOGIC MEMOR™ 1 2 2.5 WPAN CONNECTION Datalogic Memor™ mobile computer models with Bluetooth® can communicate with other Bluetooth® enabled device

Pagina 51

CONNECTIONS 2 2.6 WWAN CONNECTION Datalogic Memor™ GSM models enhance your connectivity solutions giving you an opening to an international wireless

Pagina 52 - 3.4 DESCRIPTION OF THE KEYS

3.5 Status Indicators ...37 3.5.1 LED Status...

Pagina 53 - Special Function Icons

DATALOGIC MEMOR™ 1 2 NOTE During a call, you can set the speaker volume by moving the joystick up and down. NOTE In case of heavy usage the Datalo

Pagina 54 - Windows CE

CONNECTIONS 2 2.7 CONNECTION CABLES  RS232 Direct Connection: 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV) RXDTXD310 29 4DSRDatalogic Memor™

Pagina 55 - Windows Mobile

DATALOGIC MEMOR™ 1 2 2.8 WIRELESS AND RADIO FREQUENCIES WARNINGS WARNING Use only the supplied or an approved replacement antenna. Unauthorized ant

Pagina 56 - Restored from

CONNECTIONS 2 WARNING An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the a

Pagina 57 - 3.5.1 LED Status

DATALOGIC MEMOR™ 1 3 3 USE AND FUNCTIONING The use of the Datalogic Memor™ depends on the application software loaded. However there are several pa

Pagina 58 - 3.5.2 Taskbar

USE AND FUNCTIONING 3 NOTE The mobile computer can also be awakened or turned off by the application program. 25

Pagina 59 - Windows Mobile Taskbars

DATALOGIC MEMOR™ 1 3 3.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap: Touch the scre

Pagina 60 - 3.6.1 Configure

USE AND FUNCTIONING 3 3.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional arrow k

Pagina 61

DATALOGIC MEMOR™ 1 3 3.2 WINDOWS MOBILE WELCOME WIZARD In Windows Mobile, at the very first Memor™ startup, following a clean boot or following a re

Pagina 62 - Scan Parameters

USE AND FUNCTIONING 3 3.3 DATA CAPTURE To capture data first of all select the barcode icon on the bottom-right side of the display and tap the &apos

Pagina 63 - Default Settings

REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Memor™ mobile computer. “Mobile comp

Pagina 64

DATALOGIC MEMOR™ 1 3 3.3.2 Imager Data Capture The Datalogic Memor™ Imager captures a picture of the entire bar code. The omni-directional scanning

Pagina 65 - 3.6.2 Capture

USE AND FUNCTIONING 3 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its siz

Pagina 66 - 3.7 CONTROL PANEL

DATALOGIC MEMOR™ 1 3 3.4 DESCRIPTION OF THE KEYS The Datalogic Memor™ provides a 23-key alphanumeric keyboard + ON/OFF key + joystick. The following

Pagina 67 - 3.7.1 Buttons

USE AND FUNCTIONING 3 Main Keys Function KEY FUNCTION It starts barcode data capture. The joystick lets you move forwards, backwards, upwards or do

Pagina 68 - 3.7.2 Registry

DATALOGIC MEMOR™ 1 3 3.4.1 Resetting the Memor™ Windows CE There are several reset methods for the Memor™. A warm boot terminates an unresponsive a

Pagina 69 - 3.7.3 Files Admin

USE AND FUNCTIONING 3 5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot. Warm Boot

Pagina 70 - Safe Setup Second Mask

DATALOGIC MEMOR™ 1 3 necessary when the Windows Mobile operating system locks up and the warm boot command does not work. To perform a cold boot, pres

Pagina 71

USE AND FUNCTIONING 3 3.5 STATUS INDICATORS 3.5.1 LED Status The Datalogic Memor™ provides three different LEDs signaling the mobile computer statu

Pagina 72

DATALOGIC MEMOR™ 1 3 3.5.2 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status

Pagina 73 - 3.7.5 Stylus Calibration

USE AND FUNCTIONING 3 Windows CE Taskbar Windows Mobile Taskbars 39

Pagina 74 - Figure 3

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Memor™ mobile computer. The user is r

Pagina 75 - Figure 4

DATALOGIC MEMOR™ 1 3 3.6 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. Decodi

Pagina 76 - 3.7.6 Volume Settings

USE AND FUNCTIONING 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters.

Pagina 77 - Volume & Sounds Window

DATALOGIC MEMOR™ 1 3 Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile

Pagina 78

USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the typ

Pagina 79

DATALOGIC MEMOR™ 1 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS LASER MODELSIMAGER MODELS MSI Disabled Not available Plessey Disabled Not available

Pagina 80 - 3.8.1 Microsoft® ActiveSync®

USE AND FUNCTIONING 3 3.6.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled

Pagina 81 - ActiveSync® Remote

DATALOGIC MEMOR™ 1 3 3.7 CONTROL PANEL From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Con

Pagina 82

USE AND FUNCTIONING 3 3.7.1 Buttons To configure the way up/down and the rest of keys control repeats, use the Up/Down Control applet (Start -> Se

Pagina 83

DATALOGIC MEMOR™ 1 3 3.7.2 Registry The REGISTRY ADMIN applet provides management of Windows CE 5.0/ Windows Mobile registry. From the Windows CE co

Pagina 84

USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because W

Pagina 85

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both l

Pagina 86

DATALOGIC MEMOR™ 1 3 - Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask. Safe Setup First Mask Then select

Pagina 87

USE AND FUNCTIONING 3 3.7.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the 802.11b/g radio, the Bluetooth® and

Pagina 88

DATALOGIC MEMOR™ 1 3 Windows Mobile Wireless Communications Window 52

Pagina 89

USE AND FUNCTIONING 3 3.7.5 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the styl

Pagina 90

DATALOGIC MEMOR™ 1 3 Figure 2 To recalibrate the touch screen on Windows Mobile, complete the following steps: 1. Select Start > Settings > Sy

Pagina 91 - 3.8.3 Windows Mobile Phone

USE AND FUNCTIONING 3 Figure 4 Startup stylus calibration on Windows CE When starting the terminal, a stylus calibration screen comes up if valid

Pagina 92 - 3.8.4 FTP Server Setup

DATALOGIC MEMOR™ 1 3 3.7.6 Volume Settings Windows CE From the Windows CE control panel main window, select the Audio applet by double tapping the

Pagina 93 - 3.10 FIRMWARE UPDATE

USE AND FUNCTIONING 3 From the Windows CE control panel main window, select the Volume & Sounds applet by double tapping the Volume & Sounds i

Pagina 94 - 4 MAINTENANCE

DATALOGIC MEMOR™ 1 3 Windows Mobile From the Windows Mobile Start Menu, select Settings > Connections tab and click the Audio icon: Audio Window

Pagina 95 - before the charging cycle

USE AND FUNCTIONING 3 To set the speaker volume during a call, click the icon on the right top of the Windows Mobile Start Menu. To set the front spe

Pagina 96

I D F E La luce laser è visibile all'occhio umano e viene emessa dalla finestra indicata nella figura. Die Laserstrahlung ist für das menschlic

Pagina 97

DATALOGIC MEMOR™ 1 3 3.8 WINDOWS CONNECTIONS To connect the Datalogic Memor™ to another device (i.e. Host PC) from Windows, several programs are av

Pagina 98

USE AND FUNCTIONING 3 NOTE Visit the following Microsoft Web site for the latest in updates and technical information: http://www.microsoft.com/windo

Pagina 99

DATALOGIC MEMOR™ 1 3 3.8.2 Bluetooth® Manager Device Setup Windows CE Bluetooth® Manager Device Setup Before turning on Bluetooth®, ensure that the

Pagina 100

USE AND FUNCTIONING 3 To create a Bluetooth® partnership between your device and another device that has Bluetooth® capabilities, ensure that the two

Pagina 101 - 5 TECHNICAL FEATURES

DATALOGIC MEMOR™ 1 3 To set up a connection: 1. From the list of available devices, double tap the one you want to activate, or select and then tap

Pagina 102

USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you

Pagina 103

DATALOGIC MEMOR™ 1 3 The icons displayed in the taskbar at the bottom of your MemorTM’s screen will show you the state of the Bluetooth connection, as

Pagina 104 - 5.2 READING DIAGRAM

USE AND FUNCTIONING 3 Windows Mobile Bluetooth® Manager Device Setup NOTE The Bluetooth Device Properties icon will only be visible if Bluetooth har

Pagina 105 - (6450*TRMN(

DATALOGIC MEMOR™ 1 3 NOTE By default, Bluetooth® is turned off. If you turn it on, and then turn off your device, Bluetooth® also turns off. When you

Pagina 106 - Ë"8NduÌ

USE AND FUNCTIONING 3 To set up a connection: 1. Double tap the device you want to activate, or select and then tap Connect. The resulting dialog

Pagina 107

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mob

Pagina 108 - 2D Codes

DATALOGIC MEMOR™ 1 3 2. Select the service you want to connect to. The following table shows the icons that display for different types of service.

Pagina 109 - GLOSSARY

USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you

Pagina 110

DATALOGIC MEMOR™ 1 3 3.8.4 FTP Server Setup The Datalogic Memor™ Windows CE Operating System includes a sample File Transfer Protocol (FTP) server.

Pagina 111

USE AND FUNCTIONING 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for the Bac

Pagina 112

DATALOGIC MEMOR™ 1 4 4 MAINTENANCE NOTE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation t

Pagina 113

MAINTENANCE 4 NOTE Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare bat

Pagina 114

DATALOGIC MEMOR™ 1 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Memor™. 2.

Pagina 115

MAINTENANCE 4 CAUTION As the battery cover is lifted, the mobile computer automatically shuts off, in order to retain data during the pack substituti

Pagina 116

DATALOGIC MEMOR™ 1 4 WARNING Installing, charging and/or any other action should be done by authorized personnel and following this manual. The bat

Pagina 117

MAINTENANCE 4 WARNING Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection dev

Commenti su questo manuale

Nessun commento