Datalogic J Series Manuale Utente

Navigare online o scaricare Manuale Utente per Computer palmari Datalogic J Series. Datalogic J Series User`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 120
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Datalogic J Series™
User’s Manual
©2004-2009 Datalogic Mobile S.r.l.
822000648 (Rev. I)
12/09
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
Vedere la pagina 0
1 2 3 4 5 6 ... 119 120

Sommario

Pagina 1 - User’s Manual

Datalogic J Series™User’s Manual©2004-2009 Datalogic Mobile S.r.l.822000648 (Rev. I)12/09www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitali

Pagina 2

ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso cor

Pagina 3 - CONTENTS

DATALOGIC J SERIES™ 4 4 MAINTENANCE NOTE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge

Pagina 4

MAINTENANCE 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows: 1. Turn off the Datalogic J Series™ PDA. 2.

Pagina 5 - REFERENCES

DATALOGIC J SERIES™ 4 4. Replace the battery pack by pressing the latch release button and pulling the battery latch down, and then by inserting it t

Pagina 6 - SAFETY REGULATIONS

MAINTENANCE 4 WARNING Use only a Datalogic Mobile approved power supply. Use of an alternative power supply will void the product warranty and may c

Pagina 7 - LASER SAFETY

DATALOGIC J SERIES™ 4 NOTE In order to guarantee an adequate operating autonomy, when replacing the battery pack the PDA checks the battery energy le

Pagina 8 - ATTENZIONE

TECHNICAL FEATURES 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic J Series™ Common Features Electrical Features Power DC supply 12 to 14

Pagina 9 - ATTENTION

DATALOGIC J SERIES™ 5 Environmental Features Working temperature ** -10° to + 50 °C / +14° to +122 °F Storage temperature -20° to +70 °C / -4° to +

Pagina 10 - RADIO COMPLIANCE

TECHNICAL FEATURES 5 Datalogic J Series™ HP Laser / RFID +Laser Optical Features Optical Features Datalogic J Series™ HP Laser Datalogic J Series™

Pagina 11 - Information for the User

DATALOGIC J SERIES™ 5 Datalogic J Series™ Imager Optical Features Optical Features Max. resolution 1D Codes 0.10 mm / 4 mils 2D Codes 0.17 mm / 6

Pagina 12 - PATENTS

TECHNICAL FEATURES 5 5.2 READING DIAGRAMS DLJS HP Laser (XXX-1XX-XXX models) Reading Zones (10° skew angle)100 200 400200 100 0 100 200 300 5006007

Pagina 13 - WEEE COMPLIANCE

The following shows the correspondence between the Datalogic J Series™ models and the Radio modules:  DLJS 5XX-XXX-XXX 802.11b (Wi-Fi) radio card 

Pagina 14

DATALOGIC J SERIES™ 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 012345

Pagina 15 - GENERAL VIEW

TEST CODES 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 12

Pagina 16

DATALOGIC J SERIES™ 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 12

Pagina 17 - 1 INTRODUCTION

GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile

Pagina 18 - 1.3 PACKAGE CONTENTS

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Flash Disk Non-volatile memory for storing applica

Pagina 19 - INTRODUCTION

business use, often for keeping schedule calendars and address book information handy. RAM Random Access Memory. Data in RAM can be accessed in rand

Pagina 20 - 1.4 INSERTING MINI SD CARD

INDEX A Accessories; 9 Available Models; 2 B Backup Directory File Management; 82 Bluetooth® Approval; vi Bluetooth® Manager Device Setup; 73 Button

Pagina 21

Replacing the Batteries; 85 Resetting the J Series; 34 S Safe Setup; 51 Safety Regulations; vi Laser Safety; vii Radio Compliance; x SAR Compliance;

Pagina 22 - 1.5 INSTALLING THE SIM CARD

09 Datalogic Mobile S.r.l. Via San Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le beschei

Pagina 23

ETSI EN 300 328 V1.7.1, OCTOBER 2006 : ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMIS

Pagina 24 - 1.5.1 Removing the SIM Card

SAR COMPLIANCE This product has been tested and found to comply with the following standards: - EN50360: product standard to demonstrate the complia

Pagina 25 - 1.6 ACCESSORIES

Datalogic J Series™User’s Manual©2004-2009 Datalogic Mobile S.r.l.822000648 (Rev. I)12/09www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitali

Pagina 26 - 1.7 OPERATING SYSTEM

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barra

Pagina 27 - 2 CONNECTIONS

 éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte  récupérer les matériaux dans le

Pagina 28 - 2.2 WLAN CONNECTION

GENERAL VIEW J CE A BD I K OPNML F GH Figure A – General View A) Data capture/Laser output window B) Scan key(s) (3) C

Pagina 30 - 2.3 WPAN CONNECTION

INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC J SERIES™ PDA DESCRIPTION The Datalogic J Series™, is the powerful Datalogic PDA. Thanks to the state-

Pagina 31 - CONNECTIONS

DATALOGIC J SERIES™ 1 1.2 AVAILABLE MODELS The Datalogic J Series™ PDA is available in different models depending on the options it is equipped with.

Pagina 32 - 2.4 WWAN CONNECTION

INTRODUCTION 1 NOTE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See paragraph 4

Pagina 33

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic J Series™ - User's Manual

Pagina 34 - 2.5 GPS CONNECTION

DATALOGIC J SERIES™ 1 1.4 INSERTING MINI SD CARD With Datalogic J Series™ PDA, it is possible to add a Mini SD Card for additional storage capacity.

Pagina 35

INTRODUCTION 1 CAUTION Follow proper ESD precautions to avoid damaging the SD. Proper ESD precautions include, but are not limited to, working on an

Pagina 36

DATALOGIC J SERIES™ 1 1.5 INSTALLING THE SIM CARD To correctly insert the SIM Card, proceed as follows: 1- Turn off the Datalogic J Series™ PDA. 2

Pagina 37

INTRODUCTION 1 4- Open the Sim Card slot by pulling up the locking plate. 5- Pull up the cardholder and insert the Sim Card with its contacts do

Pagina 38 - 2.6 CRADLE CONNECTIONS

DATALOGIC J SERIES™ 1 1.5.1 Removing the SIM Card To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slo

Pagina 39 - 2.7 CONNECTION CABLES

INTRODUCTION 1 1.6 ACCESSORIES  Cradles 94A151096 DLJS Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB communicati

Pagina 40 - 3 USE AND FUNCTIONING

DATALOGIC J SERIES™ 1 NOTE Use only a Datalogic Mobile-approved power supply and cables. Use of an alternative power supply will invalidate any appro

Pagina 41 - USE AND FUNCTIONING

CONNECTIONS 2 2 CONNECTIONS 2.1 RS232/USB DIRECT CONNECTION You can use a cable to connect the Datalogic J Series™ PDA to a host computer to transf

Pagina 42 - Welcome Wizard Screen

DATALOGIC J SERIES™ 2 2.2 WLAN CONNECTION Datalogic J Series™ Wi-Fi 802.11b and Wi-Fi 802.11b/g1 models can communicate with the host using the on-bo

Pagina 43 - 3.3 USING THE STYLUS

CONNECTIONS 2 NOTE Wi-Fi module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communications applet (s

Pagina 44 - 3.4.1 Laser Data Capture

CONTENTS REFERENCES ... v Conventions...

Pagina 45 - 3.4.2 Imager Data Capture

DATALOGIC J SERIES™ 2 2.3 WPAN CONNECTION Datalogic J Series™ PDAs can communicate with a Bluetooth® device, such as a printer, within a range of 10

Pagina 46 - 3.4.3 RFID Data Capture

CONNECTIONS 2 NOTE Area coverage and Bluetooth® radio performance may vary, due to environmental conditions or interference caused by other devices (

Pagina 47 - 3.5 DESCRIPTION OF THE KEYS

DATALOGIC J SERIES™ 2 2.4 WWAN CONNECTION Datalogic J Series™ GSM/GPRS models enhance your connectivity solutions giving you an opening to an interna

Pagina 48 - 3.5.2 Key Selection

CONNECTIONS 2 NOTE The GSM voice capability of this mobile computer has to be addressed to occasional use, in well covered areas. If the coverage is

Pagina 49

DATALOGIC J SERIES™ 2 2.5 GPS CONNECTION Datalogic J Series™ GPS model provides a GPS Connection to allow for both satellite communications (if equip

Pagina 50 - Windows CE

CONNECTIONS 2 To locate a position, the Datalogic J Series™ GPS must be outdoors to obtain the best possible reception. First-time initialisation of G

Pagina 51 - Windows Mobile

DATALOGIC J SERIES™ 2 NOTE The user must ensure that the Datalogic J Series™ GPS is placed correctly for optimal GPS signal reception and stays in pl

Pagina 52

CONNECTIONS 2 CAUTION Before using the Datalogic J Series™ GPS, the user should become familiar with the laws and regulations relating to satellite

Pagina 53 - 3.6.1 LED Status

DATALOGIC J SERIES™ 2 2.6 CRADLE CONNECTIONS The Datalogic J Series™ can also communicate via RS232, USB and Ethernet, using various cradle models. F

Pagina 54 - 3.6.2 Taskbar

CONNECTIONS 2 2.7 CONNECTION CABLES The following cables are listed with their order number.  RS232 Direct Connection: 94A051008 WIN-NET SERIAL

Pagina 55 - Windows Mobile Taskbars

3.5 Description of the Keys ...31 3.5.1 System Control and Navigation K

Pagina 56 - 3.7.1 Configure

DATALOGIC J SERIES™ 3 3 USE AND FUNCTIONING The use of the Datalogic J Series™ PDA depends on the application software loaded. However there are se

Pagina 57

USE AND FUNCTIONING 3 When it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel, the P

Pagina 58 - Scan Parameters

DATALOGIC J SERIES™ 3 3.2 WINDOWS MOBILE WELCOME WIZARD In Windows Mobile, at the very first J Series™ startup, following a cold boot or following a

Pagina 59

USE AND FUNCTIONING 3 3.3 USING THE STYLUS The stylus selects items and enters information. The stylus functions like a mouse. Tap: Touch the scre

Pagina 60 - Default Settings

DATALOGIC J SERIES™ 3 3.4 DATA CAPTURE To capture data, first of all select the barcode icon on the bottom-right side of the display and tap the &apo

Pagina 61

USE AND FUNCTIONING 3 3.4.2 Imager Data Capture To read a 1D or 2D code, simply point the Datalogic J Series™ Imager model onto the code from a dist

Pagina 62 - 3.7.2 Capture

DATALOGIC J SERIES™ 3 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its siz

Pagina 63 - 3.8 CONTROL PANEL

USE AND FUNCTIONING 3 3.5 DESCRIPTION OF THE KEYS The Datalogic J Series™ PDA provides a function-oriented keyboard having a total of 27 keys. The k

Pagina 64 - 3.8.1 Buttons

DATALOGIC J SERIES™ 3 3.5.2 Key Selection The following figure shows the Datalogic J Series™ PDA keyboard: Some of these keys carry extra symbol

Pagina 65

USE AND FUNCTIONING 3 It starts Data capture. The ORANGE key pressed simultaneously along with any other keyboard key enables the character positi

Pagina 66 - 3.8.2 Registry

REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic J Series™ PDA. “Mobile computer”, “P

Pagina 67 - 3.8.3 Files Admin

DATALOGIC J SERIES™ 3 3.5.3 Resetting the J Series Windows CE There are several reset methods for the J Series. A warm boot terminates an unrespon

Pagina 68 - Safe Setup Second Mask

USE AND FUNCTIONING 3 To perform a clean boot, follow these steps: 1. Perform a Cold Boot (see Cold Boot). 2. Quickly release all the keys when the

Pagina 69

DATALOGIC J SERIES™ 3 Cold Boot A cold boot is a complete reset of the J Series in which all applications are forcibly closed and the RAM is completel

Pagina 70

USE AND FUNCTIONING 3 3.6 STATUS INDICATORS 3.6.1 LED Status The Datalogic J Series™ provides three different LEDs signaling the PDA status. LED ST

Pagina 71 - GPS Startup

DATALOGIC J SERIES™ 3 3.6.2 Taskbar As well as tasks opened in Windows, the Taskbar provides several status icons that report information about the t

Pagina 72

USE AND FUNCTIONING 3 Windows CE Taskbar Windows Mobile Taskbars 39

Pagina 73

DATALOGIC J SERIES™ 3 3.7 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. Decodi

Pagina 74

USE AND FUNCTIONING 3 The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control

Pagina 75 - GPS Sample

DATALOGIC J SERIES™ 3 Selecting Data Capture Setup Parameters Alternatively using the stylus, you can tap once directly on the value on the right

Pagina 76

USE AND FUNCTIONING 3 ContinuousMode: when enabled, the scanner can only be turned off by releasing the SCAN key, or if Soft Trigger is enabled, by th

Pagina 77 - Windows CE Ethernet Cradle

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic J Series™ PDA. The user is responsibl

Pagina 78

DATALOGIC J SERIES™ 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type

Pagina 79

USE AND FUNCTIONING 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS HP Laser Imager RFID+Laser MSI Enabled Disabled Plessey Disabled Code 93 Di

Pagina 80 - 3.8.7 Stylus Calibration

DATALOGIC J SERIES™ 3 3.7.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled t

Pagina 81 - Figure 3

USE AND FUNCTIONING 3 3.8 CONTROL PANEL From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Co

Pagina 82 - Figure 4

DATALOGIC J SERIES™ 3 3.8.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3,

Pagina 83 - 3.8.8 Volume Settings

USE AND FUNCTIONING 3 Select the “Enable Multipress” check box to enable multipress text input mode. To enables F5, F6, F7, F8, F9, F10 function keys,

Pagina 84 - Input Tab

DATALOGIC J SERIES™ 3 3.8.2 Registry The REGISTRY ADMIN applet provides management of Windows CE/ Windows Mobile registry. From the Windows CE cont

Pagina 85 - Cradle Tab

USE AND FUNCTIONING 3 3.8.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because W

Pagina 86

DATALOGIC J SERIES™ 3 - Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask. Safe Setup First Mask − Then sel

Pagina 87 - 3.9.1 Microsoft® ActiveSync®

USE AND FUNCTIONING 3 3.8.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the Wi-Fi Card, the Bluetooth® and GSM/

Pagina 88 - ActiveSync® Remote

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both La

Pagina 89

DATALOGIC J SERIES™ 3 If the PDA supports Windows Mobile, the Wireless Manager application manages access to wireless connections. The 'Wireless

Pagina 90

USE AND FUNCTIONING 3 3.8.5 GPS Settings To access to GPS connection, you have to install a commercial GPS navigation software, which is available fr

Pagina 91

DATALOGIC J SERIES™ 3 Tap Programs to choose the program port to be used to obtain GPS data: 56

Pagina 92

USE AND FUNCTIONING 3 Tap Hardware to select the hardware port to which the GPS device is connected: Tap Access to manage access to the GPS device.

Pagina 93

DATALOGIC J SERIES™ 3 Tap Advanced and select the “Enable GPS” check box to enable GPS. Select the “Enable GPS at reboot” check box to re-enable GPS

Pagina 94

USE AND FUNCTIONING 3 GPS Sample To start the GPS Sample, do the following steps: tap Start -> Programs -> GPS Sample: 59

Pagina 95

DATALOGIC J SERIES™ 3 Tap GPS and select Start GPS to start the sample: As soon as the GPS receiver locates a position, all the GPS data will appea

Pagina 96

USE AND FUNCTIONING 3 3.8.6 Ethernet Settings Windows CE Ethernet Cradle Datalogic J Series™ can be connected to an Ethernet network by inserting it

Pagina 97 - 3.9.3 FTP Server Setup

DATALOGIC J SERIES™ 3 The LAN icon will appear on the Taskbar indicating the LAN connection status. By double tapping on the LAN icon in the Taskbar,

Pagina 98

USE AND FUNCTIONING 3 Windows Mobile Ethernet Cradle Before using the ethernet cradle you have to un-check the 'COM1 Enable' option on the

Pagina 99

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your PDA

Pagina 100 - 4 MAINTENANCE

DATALOGIC J SERIES™ 3 3.8.7 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the styl

Pagina 101 - MAINTENANCE

USE AND FUNCTIONING 3 Figura 2 To recalibrate the touch screen on Windows Mobile, complete the following steps: 1. Select Start > Settings > S

Pagina 102 - CAUTION

DATALOGIC J SERIES™ 3 2. Tap Align Screen to open the Calibration screen shown in Figure 4. 3. Carefully press and briefly hold stylus on the center

Pagina 103 - WARNING

USE AND FUNCTIONING 3 3.8.8 Volume Settings From the Windows CE control panel main window, select the VOLUME SETTINGS applet by double tapping the Vo

Pagina 104 - 4.3 CLEANING THE PDA

DATALOGIC J SERIES™ 3 − GSM: it is automatically activated each time a phone-call is started. It is not available when using the cradle loudspeaker (

Pagina 105 - 5 TECHNICAL FEATURES

USE AND FUNCTIONING 3 Cradle Tab It allows selecting the cradle type and managing the vehicle cradle headset functioning: Two radio buttons allo

Pagina 106

DATALOGIC J SERIES™ 3 WARNING Do not use the vehicle cradle headset if the headset button is disabled, since it may cause hearing damage. 70

Pagina 107

USE AND FUNCTIONING 3 3.9 WINDOWS CONNECTIONS To connect the PDA to another device (i.e. Host PC) from Windows, several programs are available. These

Pagina 108

DATALOGIC J SERIES™ 3 NOTE In Windows Mobile before using the ActiveSync follow the directions described in 2.1 NOTE Visit the following Microsoft

Pagina 109 - 5.2 READING DIAGRAMS

USE AND FUNCTIONING 3 3.9.2 Bluetooth® Manager Device Setup Windows CE Bluetooth® Manager Device Setup In order to enable a Bluetooth® device for

Pagina 110 - (6450*TRMN(

DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen

Pagina 111 - Ë"8NduÌ

DATALOGIC J SERIES™ 3 3. Tap on the “Me” button to enter the related window; then, tap on the “ON” button to activate the Bluetooth® module. The modu

Pagina 112

USE AND FUNCTIONING 3 Once the Discovery procedure has been completed, select the desired Bluetooth® device from the list. It is also possible to digi

Pagina 113 - GLOSSARY

DATALOGIC J SERIES™ 3 Windows Mobile Bluetooth® Manager Device Setup Before turning on Bluetooth®, ensure that the two devices are within close range

Pagina 114

USE AND FUNCTIONING 3 3. Tap the name of the other device, and tap Next: 4. In Passkey, if you want to use a passkey (recommended for enhanced

Pagina 115

DATALOGIC J SERIES™ 3 5. Enter the same passkey on the other device. 6. To give the partnership a more meaningful name, change the name of the de

Pagina 116

USE AND FUNCTIONING 3 Other devices with Bluetooth® capabilities can detect your device and attempt to beam information to it, establish a partnersh

Pagina 117

DATALOGIC J SERIES™ 3 If you no longer want your device to be discoverable, clear the “Make this device visible to other devices” check box. Your dev

Pagina 118

USE AND FUNCTIONING 3 3.9.3 FTP Server Setup The Datalogic J Series™ Windows CE Operating System includes a sample File Transfer Protocol (FTP) serve

Pagina 119

DATALOGIC J SERIES™ 3 3.10 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE system files reside in RAM (volatile memory) except for the Backup

Pagina 120

USE AND FUNCTIONING 3 3.11 FIRMWARE UPDATE FOR WINDOWS CE The Datalogic J Series™ is equipped with a tool that implements a firmware update service.

Commenti su questo manuale