82200147012/13www.datalogic.com© 2008-2013 Datalogic ADC S.r.l. All rights reserved. Datalogic and the Datalogic logo are registered trademarks of D
1 DATALOGIC MEMOR™ 2 1 Durability ratings protect the computing investment against accidental drops and occasional exposure to liquids and dust. A
1 DATALOGIC MEMOR™ 92 5 Datalogic Memor SE4500-DL Typical Reading Diagram - Reading Zones (10° skew angle) 50 100 150 200 0 100 50 150 200 mm 0
TEST CODES 93 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 01234567
1 DATALOGIC MEMOR™ 94 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784
TEST CODES 95 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 Ì
1 DATALOGIC MEMOR™ 96 6 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example
97 SAFETY REGULATIONS Read this manual carefully before performing any type of connection to the Datalogic Memor mobile computer. The user is re
6 98 LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies
99 I D F E La luce laser è visibile all'occhio umano e viene emessa dalla finestra indicata nella figura. Die Laserstrahlung ist für das m
6 100 ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of
101 Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. L’apertura dello scomparto, o la manutenzion
INTRODUCTION 3 1 1.2 AVAILABLE MODELS The Datalogic Memor is available in different models depending on the options it is equipped with. All optio
6 102 Unter keinen Umständen darf versucht werden, die Komponenten im Optikhohlraum zu öffnen oder auf irgendwelche andere Weise zu warten. Das
103 L'utilisation de procédures ou réglages différents de ceux donnés ici peut entraîner une dangereuse exposition à lumière laser visible.
6 104 El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duraci
105 RADIO COMPLIANCE In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spect
6 106 Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country
107 FCC COMPLIANCE FCC Regulations • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (
6 108 RF EXPOSURE INFORMATION (SAR) This model device meets the government’s requirements for exposure to radio waves. This device is designed a
109 INDUSTRY CANADA COMPLIANCE Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this devi
6 110 WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bid
111 Information aux utilisateurs concernant la Directive Européenne 2002/96/EC Au terme de sa vie utile, le produit qui porte le symbole d'un
1 DATALOGIC MEMOR™ 4 1 1.3 PACKAGE CONTENTS The Datalogic Memor package contains: − 1 Datalogic Memor mobile computer − 1 AC/DC power supply −
6 112 CHINA ROHS POLLUTION CONTROL LOGOS Part name Toxic or Hazardous Substances and Elements for DL-MEMOR Pb Hg Cd Cr6+ PBB PBDE Upper Case O O
113 GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped
114 Decode To recognize a bar code symbology (e.g., Codabar, Code 128, Code 3 of 9, UPC/EAN, etc.) and convert the content of the bar code scann
115 IEEE 802.11 A set of standards carrying out wireless local area network (WLAN) computer communication in the 2.4, 3.6 and 5 GHz frequency band
116 TDMA Time division multiple access (TDMA) is digital transmission technology that allows a number of users to access a single radio-frequency
117 INDEX A Accessories; 8 Audio Settings; 56 Available Models; 3 B Batteries and Maintenance; 9 Bluetooth® Manager Device Setup; 60 C Charging th
118 T Taskbar; 43 Technical Data; 87 Technical Features; 87 Test Codes; 93 U Using the Joystick; 31 Using the Stylus; 30 W WEEE Compliance; 152 Wi
13 DECLARATION OF CONFORMITY Datalogic ADC S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that t
13 DECLARATION OF CONFORMITY Datalogic ADC S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that t
ETSI EN 300 328 V1.7.1, OCTOBER 2006 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSM
INTRODUCTION 5 1 1.4 INSERTING A MICROSD CARD The Datalogic Memor supports microSD memory cards. To access the microSD card slot and insert the ca
82200147012/13www.datalogic.com© 2008-2013 Datalogic ADC S.r.l. All rights reserved. Datalogic and the Datalogic logo are registered trademarks of D
1 DATALOGIC MEMOR™ 6 1 4. Shift the cardholder to the left and then pull it up; insert the microSD card with the written part upward: 5.
INTRODUCTION 7 1 1.4.1 Removing the MicroSD Card To remove the microSD card, follow the steps above to access the SD area, and remove it from its
1 DATALOGIC MEMOR™ 8 1 1.5 ACCESSORIES Cradles 94A151111 DL-Memor Single Cradle w Aux. Slot 94A151121 Dock Memor Vehicle w Power Adapter 94A
BATTERIES AND MAINTENANCE 9 2 2 BATTERIES AND MAINTENANCE Rechargeable backup batteries and battery packs are not initially fully charged. There
1 DATALOGIC MEMOR™ 10 2 Do not use the Datalogic Memor until batteries are charged for minimum 4 hours. CAUTION Risk of explosion if battery
BATTERIES AND MAINTENANCE 11 2 The Datalogic Memor may get warm during charging; this is normal and does not mean a malfunction. NOTE Use only a
Datalogic ADC S.r.l. Via S. Vitalino, 13 40012 Lippo di Calderara di Reno Bologna - Italy Telephone: (+39) 051-3147011 Fax: (+39) 051-3147205 ©2008
1 DATALOGIC MEMOR™ 12 2 2.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Mem
BATTERIES AND MAINTENANCE 13 2 4. Install the new battery pack, first insert the bottom (contacts) side, then the upper side: 5. Press the latc
1 DATALOGIC MEMOR™ 14 2 WARNING Immediately discontinue use of the battery pack if, while using, charging or storing the battery pack, the batte
BATTERIES AND MAINTENANCE 15 2 In order to maximize operating autonomy, the Datalogic Memor checks its battery level at all times. If the battery
1 DATALOGIC MEMOR™ 16 2 2.3 CLEANING THE MOBILE COMPUTER Periodically clean the Datalogic Memor with a slightly dampened cloth. Do not use alc
CONNECTIONS 17 3 3 CONNECTIONS 3.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Datalogic Memor to a host com
1 DATALOGIC MEMOR™ 18 3 The Single Dock can be connected to the host computer by any standard mini USB cable. Once the host computer has been tu
CONNECTIONS 19 3 3.2 CONNECTION TO USB PERIPHERALS You can connect the Datalogic Memor to a standard 101-key USB keyboard or to a standard USB fla
1 DATALOGIC MEMOR™ 20 3 Datalogic Memor works with most of the mentioned USB peripherals. Datalogic cannot guarantee the interoperability of Da
CONNECTIONS 21 3 3.3 RS232 CONNECTION You can use a cable to directly connect the Datalogic Memor to a host computer to transfer data through the
iii CONTENTS REFERENCES ... vi Conventions ...
1 DATALOGIC MEMOR™ 22 3 3.4 WLAN CONNECTION The Datalogic Memor 802.11 abg radio models can communicate with the host using the on-board Wi-Fi r
CONNECTIONS 23 3 802.11 abg radio module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communicatio
1 DATALOGIC MEMOR™ 24 3 3.5 WPAN CONNECTIONS The Datalogic Memor Bluetooth® models can communicate with a Bluetooth® device, such as a printer,
CONNECTIONS 25 3 3.6 CONNECTION CABLES RS232 Direct Connection: 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV) RXD TXD 3 10 2 9 4 DSR Dat
1 DATALOGIC MEMOR™ 26 3 3.7 WIRELESS AND RADIO FREQUENCIES WARNINGS Use only the supplied or an approved replacement antenna. Unauthorized ant
CONNECTIONS 27 3 Turn this device OFF in health care facilities when any regulations posted in these areas instruct you to do so. Hospitals or hea
1 DATALOGIC MEMOR™ 28 4 4 USE AND FUNCTIONING The use of the Datalogic Memor depends on the application software loaded. However there are sev
USE AND FUNCTIONING 29 4 defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key.
1 DATALOGIC MEMOR™ 30 4 4.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap: Touch t
USE AND FUNCTIONING 31 4 4.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional ar
iv 4.5.2 Capture ... 51 4.5.3 Buttons ...
1 DATALOGIC MEMOR™ 32 4 4.1.3 Windows Mobile Welcome Wizard In Windows Mobile, at the very first Datalogic Memor startup, following a clean boot
USE AND FUNCTIONING 33 4 4.2 DATA CAPTURE To capture data tap Start > Settings > System > Decoding: To configure and enable data captu
1 DATALOGIC MEMOR™ 34 4 4.2.1 Laser Data Capture To scan barcodes, point the Datalogic Memor laser model onto the code from a distance within t
USE AND FUNCTIONING 35 4 4.2.2 Imager Data Capture The Datalogic Memor Imager captures a picture of the entire bar code. The omni-directional scan
1 DATALOGIC MEMOR™ 36 4 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes
USE AND FUNCTIONING 37 4 4.3 DESCRIPTION OF THE KEYBOARDS The Datalogic Memor comes with a 23-key alphanumeric keyboard + ON/OFF key + joystick.
1 DATALOGIC MEMOR™ 38 4 Main Keys Function KEY FUNCTION The SCAN key starts data capture. The joystick lets you move forwards, backwards, upw
USE AND FUNCTIONING 39 4 After a blue modifier key press, it locks and unlocks the keyboard.
1 DATALOGIC MEMOR™ 40 4 4.3.1 Resetting the Datalogic Memor There are several reset methods for the Datalogic Memor. A warm boot terminates an
USE AND FUNCTIONING 41 4 Clean Boot A clean boot is a cold boot that causes the device to be restored to factory configuration. The Datalogic Memor
v WEEE Compliance ... 110 China RoHS Pollution Control Logos ...
1 DATALOGIC MEMOR™ 42 4 4.4 STATUS INDICATORS 4.4.1 LED Status The Datalogic Memor provides two different LEDs signaling the mobile comput
USE AND FUNCTIONING 43 4 4.4.2 Taskbar Windows Mobile 6.1 Taskbars The Taskbar provides information about the time, the battery level, the ke
1 DATALOGIC MEMOR™ 44 4 4.5 SETTINGS From the Start menu, tap Settings. The settings are organized hierarchically. Control panel applets are d
USE AND FUNCTIONING 45 4 4.5.1 Data Capture Configuration From the Start menu, tap Settings -> System -> Decoding. The "Decoding"
1 DATALOGIC MEMOR™ 46 4 Configure The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure.
USE AND FUNCTIONING 47 4 Selecting Data Capture Setup Parameters Alternatively using the stylus, you can tap once directly on the value on the
1 DATALOGIC MEMOR™ 48 4 BeepType: if set to dual tone, the good read beep is a sequence of high and low pitch sounds. If set to monotone, the beep
USE AND FUNCTIONING 49 4 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the
1 DATALOGIC MEMOR™ 50 4 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS LASER MODELS IMAGER MODELS MSI Disabled Not available Plessey Disabled Not a
USE AND FUNCTIONING 51 4 4.5.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be e
1 vi REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Memor mobile computer. “Mobil
1 DATALOGIC MEMOR™ 52 4 4.5.3 Buttons Tap Start > Settings > Personal > Buttons. You can use the Up/Down Control tab to customize the w
USE AND FUNCTIONING 53 4 4.5.4 Wireless Communications The Wireless Communications applet provides management of the 802.11 abg radio and the Blue
1 DATALOGIC MEMOR™ 54 4 4.5.5 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with t
USE AND FUNCTIONING 55 4 3. Carefully press and briefly hold stylus on the center of the target. Repeat as the target moves around the screen. Pres
1 DATALOGIC MEMOR™ 56 4 4.5.6 Audio Settings There are two applets that control volume: Audio and Sounds & Notifications. Audio From the St
USE AND FUNCTIONING 57 4 Sounds & Notifications From the Start Menu, tap Settings > Personal > Sounds and Notifications: The Sounds &
1 DATALOGIC MEMOR™ 58 4 You can also set the volume of a paired Bluetooth® headset. Tap Start > Settings > Connections > Bluetooth Mana
USE AND FUNCTIONING 59 4 4.6 CONNECTING TO OTHER COMPUTERS To connect the Datalogic Memor to another device (i.e. Host PC) which run Windows, se
1 DATALOGIC MEMOR™ 60 4 4.6.2 Bluetooth® Manager Device Setup Using the Datalogic Memor to connect to another device To create a Bluetooth® p
USE AND FUNCTIONING 61 4 2. From the Bluetooth Manager control panel tap ‘Connections’. 3. Search for available Bluetooth® devices by tapping
vii GENERAL VIEW A) QVGA 64K Color Display B) Good Read or User Programmable LED C) Charging Status LED D) Speaker E) Scan Key F) Keyb
1 DATALOGIC MEMOR™ 62 4 4. Once searching is complete, Bluetooth® devices will be displayed in the Discovery tab. You can set up a connection to
USE AND FUNCTIONING 63 4 To create a pairing: 1. Select a service: 2. Configure any encryption, authentication, or virtual port options requir
1 DATALOGIC MEMOR™ 64 4 Icon Service Dialup Networking Printer Object Push (OPP) Object Exchange (OBEX) ActiveSync Human Interface Device (
USE AND FUNCTIONING 65 4 You can also select Encrypt or Authenticate from the Bluetooth® control panel to apply or modify those settings. 1. To re
1 DATALOGIC MEMOR™ 66 4 Once you have set up a pairing, you can view the settings by double-tapping its name from the Connections tab. Tap the arr
USE AND FUNCTIONING 67 4 Using your device to connect to the Datalogic Memor Before turning on Bluetooth®, ensure that the two devices are within c
1 DATALOGIC MEMOR™ 68 4 3. Select or clear the “Enable Bluetooth Radio” check box. If you’re going to be attaching a serial device (i.e. a sca
USE AND FUNCTIONING 69 4 4.7 DATALOGIC FIRMWARE UTILITY The Datalogic devices are equipped with a field upgradeable firmware mechanism. Firmware u
1 DATALOGIC MEMOR™ 70 4 4.7.2 Installing DFU on the Host PC Datalogic Firmware Utility (DFU) provides administrators with a field upgrade mechan
USE AND FUNCTIONING 71 4 4.7.3 Updating the Firmware After copying the firmware image to the host PC (see par. 4.10.1) and installing DFU (see par
1 viii N) Data Capture Window* O) DC Charger Connector P) Communication/Charger Connector (through cradle) Q) Mini USB Communicat
1 DATALOGIC MEMOR™ 72 4 4.8 DATALOGIC CONFIGURATION UTILITY Datalogic Configuration Utility (DCU) is a Datalogic Windows-based utility tool allo
USE AND FUNCTIONING 73 4 4.9 DATALOGIC DESKTOP UTILITY Datalogic Desktop Utility (DDU) allows administrators to configure Windows® CE and Embedde
1 DATALOGIC MEMOR™ 74 4 4.9.1 Administrative Options (Admin tab) When you open the DDU control panel, the “Admin” tab appears. COMMAND DESCR
USE AND FUNCTIONING 75 4 Setting a Password To set a password: 1. Enter a password in the field. This allows the user to specify a password when
1 DATALOGIC MEMOR™ 76 4 Removing a Password To remove a password: 1. Enter blanks in both “Password” fields. 2. Select/tap “Set Password”. P
USE AND FUNCTIONING 77 4 4.9.2 Setting Hot Keys You can use Hot Keys (HKeys) Tab to associate specific keys, such as <F1>-<F10>, with
1 DATALOGIC MEMOR™ 78 4 Browse Select/tap to browse for application files. You can associate an executable program with the specified Hot Key. Ar
USE AND FUNCTIONING 79 4 Adding a new Hot Key When you select ‘New’ on the HKeys tab, this opens the Add New Hotkey dialog box. To define a new Ho
1 DATALOGIC MEMOR™ 80 4 It is possible for the keyboard wedge to activate assigned Hot Keys using alphanumeric characters. Barcodes containing c
USE AND FUNCTIONING 81 4 4.9.3 Internet Explorer Configuration Tap the IE (Internet Explorer) tab to access the IE Configuration option. Use the I
INTRODUCTION 1 1 1 INTRODUCTION 1.1 DATALOGIC MEMOR DESCRIPTION The Datalogic Memor mobile computer maximizes a compact and light weight form f
1 DATALOGIC MEMOR™ 82 4 4.9.4 Modifying Windows Controls Select/tap the “Win” (Windows Controls) tab to access the Windows Controls option. Use
USE AND FUNCTIONING 83 4 4.9.5 AppSelector Options (AppSelect tab) Tap the Application Selector (“AppSelect” Tab) to edit, add, or delete applicat
1 DATALOGIC MEMOR™ 84 4 Add Applications The “Add Application” dialog opens when you tap either “New” or “Edit”. From the “Add Application” dialo
USE AND FUNCTIONING 85 4 COMMAND DESCRIPTION Run Application at Startup Select/tap this box to force this application to auto start when the Applic
1 DATALOGIC MEMOR™ 86 4 4.10 APPSELECTOR (APPLICATION SELECTOR) The Application Selector is an application that allows a device to run in kiosk
TECHNICAL FEATURES 87 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA PHYSICAL CHARACTERISTICS DIMENSIONS (LxWxH) 15.2 x 5.5 x 4.0 cm / 5.9 x 2.2 x 1
1 DATALOGIC MEMOR™ 88 5 SYSTEM OPERATING SYSTEM Windows CE 5.0 Professional MICROPROCESSOR Marvell XScale™ PXA310 @ 624 MHz SYSTEM RAM MEMORY
TECHNICAL FEATURES 89 5 READING OPTIONS LASER CHARACTERISTICS SCANNING RATE - BIDIRECTIONAL 104 ± 12 scan/sec OPTICAL RESOLUTION 0.10 mm / 4 mils
1 DATALOGIC MEMOR™ 90 5 READING OPTIONS LASER CLASSIFICATION Laser: Class 2 Safety class: N 60825-1:2001 LED CLASSIFICATION Led (Illuminator): Cl
TECHNICAL FEATURES 91 5 5.2 READING DIAGRAMS Datalogic Memor 1D Typical Reading Diagram - Reading Zones (10° skew angle) 100 200 300 400 0 200
Commenti su questo manuale