RAPID CONFIGURATION
11
1
d. Hardware interface selection
e. Output data format configuration
The On Line operating Mode requires the reader to be connected to an External
Trigger/Presence Sensor using I1A and I1B inputs.
The Automatic operating mode does not require connection to an external Presence
Sensor. When working in this mode the reader is continuously scanning, while the
reading phase is activated each time a barcode enters the reader reading zone. The
reader stops reading after an N number of scans without a code. Barcode characters
are transmitted on the serial interface. In case of a failed reading phase no message is
sent to the host computer.