Datalogic QuickScan Lite QW2100 Specifiche Pagina 211

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 324
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 210
Standard 2 of 5
Product Reference Guide 201
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 — cont.
Standard 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length
2 is the maximum label length if in
Variable Length Mode, or the second fixed length if in
Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See
Set Length 2 on page 269 for more detailed programming
instructions.
$CS2L2
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters