Programming Guide 21
RS-232 ACK/NAK Options
(QuickScan 6000 Plus ONLY)
Several ACK/NAK parameters can be set for your QuickScan 6000 Plus
scanner. Contact your Datalogic dealer if the specific ACK/NAK option you wish to
set is not included in this section.
Options for RS-232 ACK/NAK are:
Disable ACK/NAK
Enable ACK/NAK for bar code transmission
Enable ACK/NAK for host command acknowledge
Enable ACK/NAK for bar code transmission and host command
acknowledge.
(These features available for QuickScan 6000 Plus ONLY)
SET ----------------------------------------------
DISABLE ACK/NAK -------------------
FOR BAR CODE TRANSMISSION --------
FOR HOST COMMAND ACKNOWLEDGE --
FOR BAR CODE TRANSMISSION --------
END ----------------------------------------------
AND HOST COMMAND ACKNOWLEDGE
ACK/NAK E
NABLE