ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Transmission
Product Reference Guide 179
Standard 2 of 5 Check Character Transmission
This feature enables/disables transmission of an optional Standard 2 of 5 check character.
Standard 2 of 5 Check Character Transmission = Don’t Send
Standard 2 of 5 Check Character Transmission = Send
DEFAULT
Standard 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must
be decoded before it is accepted as good read.
Standard 2 of 5 Minimum Reads = 1
Standard 2 of 5 Minimum Reads = 2
DEFAULT
Standard 2 of 5 Minimum Reads = 3
Standard 2 of 5 Minimum Reads = 4