2.5.3 Fixed Mode
Fixed mode allows you to position the laser beam at any angle between +20° and
-20° with respect to the mounting position of the scanner.
To use the OM4000 in this mode:
1. Set the Min Position switch to 0.
2. Set the Max Position switch to the correct value for your application between 1-
F. (the laser will move to the value aiding the configuration)
The MODE and FREQUENCY switch settings are indifferent.
Example:
0 = disabled
MIN POSITION
MAX POSITION
4 = -12°
FIXED MODE
Figure 13 – Fixed mode
Vedere la pagina 19